{"title":"EtherCAT P","description":"","products":[{"product_id":"aufputz-aussen-feuchtraum-temperaturmessumformer-thermasgard-atm2-ecatp-ip54-ethercat-p-kabelverschraubung-2001-6201-9100-001","title":"THERMASGARD® ATM2-ECATP","description":"Networkable outdoor temperature measuring transducer THERMASGARD® ATM2 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe surface-mounted sensor is used to measure the temperature in gaseous media. It is used outdoors or in damp rooms, in cold stores and greenhouses, in industry and in agriculture. Installation on external walls is preferably on the north side or in a protected location. In direct sunlight, the WS 03 weather and sun protection (accessory) must be used. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bar graph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51254856057163,"sku":"2001-6201-9100-001","price":381.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ATM2-ECATP__tyr2_maxi-mL_4c.png?v=1769647761"},{"product_id":"aufputz-aussen-feuchtraum-temperaturmessumformer-thermasgard-atm2-ecatp-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-6202-9100-001","title":"THERMASGARD® ATM2-ECATP LCD","description":"Networkable outdoor temperature measuring transducer THERMASGARD® ATM2 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe surface-mounted sensor is used to measure the temperature in gaseous media. It is used outdoors or in damp rooms, in cold stores and greenhouses, in industry and in agriculture. Installation on external walls is preferably on the north side or in a protected location. In case of direct sunlight, the weather and sun protection WS 03 (accessory) must be used. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51254857138507,"sku":"2001-6202-9100-001","price":432.61,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ATM2-ECATP-LCD__tyr2_maxi-mL_4c.png?v=1769647809"},{"product_id":"anlegetemperaturmessumformer-rohranlegefuehler-thermasgard-altm2-ecatp-ip54-ethercat-p-kabelverschraubung-2001-2171-9100-001","title":"THERMASGARD® ALTM2-ECATP","description":"Networkable contact temperature measuring transducer (remote version) THERMASGARD® ALTM2 - EtherCATP with M8 plug connectors (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, cable sensor with pipe feeder, incl. clamping strap. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eThe pipe contact sensor is used to measure the temperature on pipes, pipes (e.g. cold and hot water) or on heating pipes for heating control. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable transmitter for industrial requirements with maximum reliability: simple integration into the PLC level via the ESI configuration file of the device, diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51254868017483,"sku":"2001-2171-9100-001","price":394.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALTM2-ECATP__tyr2_maxi-mL_4c.png?v=1769647108"},{"product_id":"anlegetemperaturmessumformer-rohranlegefuehler-thermasgard-altm2-ecatp-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-2172-9100-001","title":"THERMASGARD® ALTM2-ECATP LCD","description":"Networkable contact temperature measuring transducer (remote version) THERMASGARD® ALTM2 - EtherCATP with M8 plug connectors (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, cable sensor with pipe feeder, incl. tensioning strap. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eThe pipe contact sensor is used to measure the temperature on pipes, pipes (e.g. cold and hot water) or on heating pipes for heating control. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable transmitter for industrial requirements with maximum reliability: simple integration into the PLC level via the ESI configuration file of the device, diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51254868541771,"sku":"2001-2172-9100-001","price":445.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALTM2-ECATP-LCD__tyr2_maxi-mL_4c.png?v=1769647172"},{"product_id":"huelsenfuehler-mit-temperaturmessumformer-thermasgard-hftm-ecatp-ip54-ethercat-p-kabelverschraubung-2001-2161-9100-001","title":"THERMASGARD® HFTM-ECATP","description":"Networkable sleeve temperature transmitter THERMASGARD® HFTM - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, cable sensor with stainless steel sleeve.\u003cbr\u003e\u003cbr\u003e The sleeve sensor is used to measure the temperature in liquid and gaseous media. It is used as a duct sensor or as an immersion and screw-in sensor in liquids by means of installation in immersion sleeve THE (accessory). The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51254902325579,"sku":"2001-2161-9100-001","price":391.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/HFTM-ECATP__tyr2_maxi-mL_4c.png?v=1769678213"},{"product_id":"huelsenfuehler-mit-temperaturmessumformer-thermasgard-hftm-ecatp-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-2162-9100-001","title":"THERMASGARD® HFTM-ECATP LCD","description":"Networkable sleeve temperature transmitter THERMASGARD® HFTM - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, cable sensor with stainless steel sleeve.\u003cbr\u003e\u003cbr\u003e The sleeve sensor is used to measure the temperature in liquid and gaseous media. It is used as a duct sensor or as an immersion and screw-in sensor in liquids by means of installation in immersion sleeve THE (accessory). The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51254902980939,"sku":"2001-2162-9100-001","price":442.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/HFTM-ECATP-LCD__tyr2_maxi-mL_4c.png?v=1769678263"},{"product_id":"mittelwerttemperaturmessumformer-thermasgard-mwtm-ecatp-0-4m-ip54-ethercat-p-kabelverschraubung-2001-4211-9100-001","title":"THERMASGARD® MWTM-ECATP 0.4m","description":"Networkable mean value temperature measuring transducer THERMASGARD® MWTM - EtherCATP with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, with flexible sensor rod (0.4...20 m, fully active) in robust protective tube made of copper with plastic coating, incl. mounting flange.\u003cbr\u003e\u003cbr\u003e The rod sensor is used to measure the average temperature (mean value) in gaseous media. It is used in ventilation and air conditioning ducts over the entire cross-section or over a defined length (installed in a meandering pattern, it evenly measures the temperature present). Mounting clamps MK-05-M (accessories) are available for professional installation of the rod. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bar graph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51254965109067,"sku":"2001-4211-9100-001","price":424.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/MWTM-ECATP__tyr2-MF-rute-04m__maxi-mL_4c.png?v=1769687211"},{"product_id":"mittelwerttemperaturmessumformer-thermasgard-mwtm-ecatp-3-0m-ip54-ethercat-p-kabelverschraubung-2001-4211-9100-011","title":"THERMASGARD® MWTM-ECATP 3.0m","description":"Networkable mean value temperature measuring transducer THERMASGARD® MWTM - EtherCATP with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, with flexible sensor rod (0.4...20 m, fully active) in robust protective tube made of copper with plastic coating, incl. mounting flange.\u003cbr\u003e\u003cbr\u003e The rod sensor is used to measure the average temperature (mean value) in gaseous media. It is used in ventilation and air conditioning ducts over the entire cross-section or over a defined length (installed in a meandering pattern, it evenly measures the temperature present). Mounting clamps MK-05-M (accessories) are available for professional installation of the rod. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bar graph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51254965469515,"sku":"2001-4211-9100-011","price":462.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/MWTM-ECATP__tyr2-MF-rute-3m-6m__maxi-mL_4c.png?v=1769687274"},{"product_id":"mittelwerttemperaturmessumformer-thermasgard-mwtm-ecatp-6-0m-ip54-ethercat-p-kabelverschraubung-2001-4211-9100-021","title":"THERMASGARD® MWTM-ECATP 6.0m","description":"Networkable mean value temperature measuring transducer THERMASGARD® MWTM - EtherCATP with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, with flexible sensor rod (0.4...20 m, fully active) in robust protective tube made of copper with plastic coating, incl. mounting flange.\u003cbr\u003e\u003cbr\u003e The rod sensor is used to measure the average temperature (mean value) in gaseous media. It is used in ventilation and air conditioning ducts over the entire cross-section or over a defined length (installed in a meandering pattern, it evenly measures the temperature present). Mounting clamps MK-05-M (accessories) are available for professional installation of the rod. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51254965731659,"sku":"2001-4211-9100-021","price":510.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/MWTM-ECATP__tyr2-MF-rute-3m-6m__maxi-mL_4c_2df78faa-bb58-443a-aa30-937ca50d821b.png?v=1769687340"},{"product_id":"mittelwerttemperaturmessumformer-thermasgard-mwtm-ecatp-0-4m-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-4212-9100-001","title":"THERMASGARD® MWTM-ECATP 0.4m LCD","description":"Networkable mean value temperature measuring transducer THERMASGARD® MWTM - EtherCATP with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, with flexible sensor rod (0.4...20 m, fully active) in robust protective tube made of copper with plastic coating, incl. mounting flange.\u003cbr\u003e\u003cbr\u003e The rod sensor is used to measure the average temperature (mean value) in gaseous media. It is used in ventilation and air conditioning ducts over the entire cross-section or over a defined length (installed in a meandering pattern, it evenly measures the temperature present). Mounting clamps MK-05-M (accessories) are available for professional installation of the rod. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51254965895499,"sku":"2001-4212-9100-001","price":475.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/MWTM-ECATP-LCD__tyr2-MF-rute-04m__maxi-mL_4c.png?v=1769687250"},{"product_id":"mittelwerttemperaturmessumformer-thermasgard-mwtm-ecatp-3-0m-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-4212-9100-011","title":"THERMASGARD® MWTM-ECATP 3.0m LCD","description":"Networkable mean value temperature measuring transducer THERMASGARD® MWTM - EtherCATP with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, with flexible sensor rod (0.4...20 m, fully active) in robust protective tube made of copper with plastic coating, incl. mounting flange.\u003cbr\u003e\u003cbr\u003e The rod sensor is used to measure the average temperature (mean value) in gaseous media. It is used in ventilation and air conditioning ducts over the entire cross-section or over a defined length (installed in a meandering pattern, it evenly measures the temperature present). Mounting clamps MK-05-M (accessories) are available for professional installation of the rod. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51254967664971,"sku":"2001-4212-9100-011","price":513.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/MWTM-ECATP-LCD__tyr2-MF-rute-3m-6m__maxi-mL_4c.png?v=1769687315"},{"product_id":"mittelwerttemperaturmessumformer-thermasgard-mwtm-ecatp-6-0m-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-4212-9100-021","title":"THERMASGARD® MWTM-ECATP 6.0m LCD","description":"Networkable mean value temperature measuring transducer THERMASGARD® MWTM - EtherCATP with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, with flexible sensor rod (0.4...20 m, fully active) in robust protective tube made of copper with plastic coating, incl. mounting flange.\u003cbr\u003e\u003cbr\u003e The rod sensor is used to measure the average temperature (mean value) in gaseous media. It is used in ventilation and air conditioning ducts over the entire cross-section or over a defined length (installed in a meandering pattern, it evenly measures the temperature present). Mounting clamps MK-05-M (accessories) are available for professional installation of the rod. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51254968058187,"sku":"2001-4212-9100-021","price":561.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/MWTM-ECATP-LCD__tyr2-MF-rute-3m-6m__maxi-mL_4c_d7189512-51ae-44c5-90fe-869e06b1205b.png?v=1769687380"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-50mm-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-4202-9100-011","title":"THERMASGARD® TM65-ECATP 50mm LCD","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, compact district heating stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255093756235,"sku":"2001-4202-9100-011","price":428.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP-LCD__tyr2_maxi-mL_4c.png?v=1762943652"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-100mm-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-4202-9100-021","title":"THERMASGARD® TM65-ECATP 100mm LCD","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, compact district heating stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255093952843,"sku":"2001-4202-9100-021","price":428.81,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP-LCD__tyr2_maxi-mL_4c_4eb327a3-2302-4e01-8f25-098a2b72e657.png?v=1762943088"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-150mm-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-4202-9100-031","title":"THERMASGARD® TM65-ECATP 150mm LCD","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, district heating compact stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bar graph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255094083915,"sku":"2001-4202-9100-031","price":429.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP-LCD__tyr2_maxi-mL_4c_e3cdca3b-c784-4a61-83cc-36300e35373e.png?v=1762943183"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-200mm-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-4202-9100-041","title":"THERMASGARD® TM65-ECATP 200mm LCD","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, compact district heating stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bar graph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255095066955,"sku":"2001-4202-9100-041","price":429.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP-LCD__tyr2_maxi-mL_4c_af5f55de-6271-4308-9e17-7d6ddf8ee8f1.png?v=1762943276"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-250mm-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-4202-9100-051","title":"THERMASGARD® TM65-ECATP 250mm LCD","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, compact district heating stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255095820619,"sku":"2001-4202-9100-051","price":430.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP-LCD__tyr2_maxi-mL_4c_36b3940f-aa81-41cc-94b5-248d69e2a260.png?v=1762943370"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-300mm-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-4202-9100-061","title":"THERMASGARD® TM65-ECATP 300mm LCD","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, compact district heating stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255096049995,"sku":"2001-4202-9100-061","price":430.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP-LCD__tyr2_maxi-mL_4c_ece7b075-a52b-40be-b758-59ab9af7958c.png?v=1762943464"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-400mm-lcd-ip54-ethercat-p-display-kabelverschraubung-2001-4202-9100-081","title":"THERMASGARD® TM65-ECATP 400mm LCD","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, district heating compact stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bar graph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255096901963,"sku":"2001-4202-9100-081","price":431.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP-LCD__tyr2_maxi-mL_4c_2f803f42-0f20-4f47-b12d-4d0d0c4e6a0d.png?v=1762943558"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-50mm-ip54-ethercat-p-kabelverschraubung-2001-4201-9100-011","title":"THERMASGARD® TM65-ECATP 50mm","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, district heating compact stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255097065803,"sku":"2001-4201-9100-011","price":377.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP__tyr2_maxi-mL_4c.png?v=1762943580"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-100mm-ip54-ethercat-p-kabelverschraubung-2001-4201-9100-021","title":"THERMASGARD® TM65-ECATP 100mm","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, district heating compact stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255097360715,"sku":"2001-4201-9100-021","price":377.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP__tyr2_maxi-mL_4c_ab93b373-6b7f-4ae4-8e50-03ce1cc5f538.png?v=1762943016"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-150mm-ip54-ethercat-p-kabelverschraubung-2001-4201-9100-031","title":"THERMASGARD® TM65-ECATP 150mm","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, district heating compact stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bar graph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255097753931,"sku":"2001-4201-9100-031","price":378.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP__tyr2_maxi-mL_4c_8b7b8dbb-1422-4d47-91e3-52463a8dcd71.png?v=1762943111"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-200mm-ip54-ethercat-p-kabelverschraubung-2001-4201-9100-041","title":"THERMASGARD® TM65-ECATP 200mm","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, district heating compact stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bar graph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255097917771,"sku":"2001-4201-9100-041","price":378.74,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP__tyr2_maxi-mL_4c_32723ea6-4589-4e95-b50f-c21b64254e1c.png?v=1762943205"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-250mm-ip54-ethercat-p-kabelverschraubung-2001-4201-9100-051","title":"THERMASGARD® TM65-ECATP 250mm","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, district heating compact stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bar graph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255098048843,"sku":"2001-4201-9100-051","price":379.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP__tyr2_maxi-mL_4c_2e3d13a6-a6c7-47d1-8118-8a0f5e5f7ad0.png?v=1762943299"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-300mm-ip54-ethercat-p-kabelverschraubung-2001-4201-9100-061","title":"THERMASGARD® TM65-ECATP 300mm","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, district heating compact stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering as well as in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255098179915,"sku":"2001-4201-9100-061","price":379.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP__tyr2_maxi-mL_4c_6ea6a257-543c-4a89-a45e-4ac3c8a0cc02.png?v=1762943393"},{"product_id":"tauch-einschraub-kanal-temperaturmessumformer-thermasgard-tm65-ecatp-400mm-ip54-ethercat-p-kabelverschraubung-2001-4201-9100-081","title":"THERMASGARD® TM65-ECATP 400mm","description":"Networkable temperature transmitter with sensor tube THERMASGARD® TM65 - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph. \u003cbr\u003e\u003cbr\u003eThe duct sensor is used to measure the temperature in liquid or gaseous media. Stainless steel immersion sleeves must be used for aggressive media (see accessories). It is used in heating technology, ventilation and air conditioning ducts, in pipelines, storage tanks, district heating compact stations, hot and cold water systems, oil and lubrication circulation systems, in mechanical and plant engineering and in the entire industrial sector. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255098900811,"sku":"2001-4201-9100-081","price":380.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/TM65-ECATP__tyr2_maxi-mL_4c_3f36f209-127d-456e-af3a-12ed506a257d.png?v=1762943487"},{"product_id":"aufputz-feuchte-und-temperaturfuehler-2-0-hygrasgard-aftf-ecatp-2003-6261-9100-001","title":"HYGRASGARD® AFTF-ECATP","description":"Networkable outdoor humidity and temperature transmitter HYGRASGARD® AFTF - EtherCATP with M8 connectors (EtherCATP-coded), Bluetooth-capable, in an impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph, with plastic sintered filter (replaceable). \u003cbr\u003e\u003cbr\u003eThe sensor is used to determine various humidity measurement technology parameters. The relative humidity (0...100 % RH) and the temperature (- 35...+80 °C) of the ambient air are measured. Further output variables are calculated internally from these measured variables: absolute humidity (0...80 g\/m³), mixing ratio (0...80 g\/kg), dew point temperature (- 20...+80 °C) and enthalpy (0...85 kJ\/kg), disregarding the atmospheric air pressure. A long-term stable, digital sensor guarantees exact measurement results. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: simple integration into the PLC level via the ESI configuration file of the device, diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, freely configurable LEDs) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255188783435,"sku":"2003-6261-9100-001","price":405.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTF-ECATP__tyr2-K_maxi-mL_4c.png?v=1769648003"},{"product_id":"aufputz-feuchte-und-temperaturfuehler-2-0-hygrasgard-aftf-ecatp-lcd-display-2003-6262-9100-001","title":"HYGRASGARD® AFTF-ECATP LCD","description":"Networkable outdoor humidity and temperature transmitter HYGRASGARD® AFTF - EtherCATP with M8 connectors (EtherCATP-coded), Bluetooth-capable, in an impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph, with plastic sintered filter (replaceable). \u003cbr\u003e\u003cbr\u003eThe sensor is used to determine various humidity measurement technology parameters. The relative humidity (0...100 % RH) and the temperature (- 35...+80 °C) of the ambient air are measured. Further output variables are calculated internally from these measured variables: absolute humidity (0...80 g\/m³), mixing ratio (0...80 g\/kg), dew point temperature (- 20...+80 °C) and enthalpy (0...85 kJ\/kg), disregarding the atmospheric air pressure. A long-term stable, digital sensor guarantees exact measurement results. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: simple integration into the PLC level via the ESI configuration file of the device, diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, freely configurable LEDs) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255189340491,"sku":"2003-6262-9100-001","price":456.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTF-ECATP-LCD__tyr2-K_maxi-mL_4c.png?v=1769648068"},{"product_id":"kanal-feuchte-und-temperaturfuehler-2-0-hygrasgard-kftf-ecatp-ethercat-p-ip54-2003-4221-9100-001","title":"HYGRASGARD® KFTF-ECATP","description":"Networkable duct humidity and temperature sensor HYGRASGARD® KFTF - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph, with plastic sintered filter (replaceable), incl. mounting flange. \u003cbr\u003e\u003cbr\u003eThe sensor is used to determine various humidity measurement parameters. The relative humidity (0...100 % RH) and the temperature (- 35...+80 °C) of the ambient air are measured. Further output variables are calculated internally from these measured variables: absolute humidity (0...80 g\/m³), mixing ratio (0...80 g\/kg), dew point temperature (- 20...+80 °C) and enthalpy (0...85 kJ\/kg), disregarding the atmospheric air pressure. A long-term stable, digital sensor guarantees exact measurement results. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255235543371,"sku":"2003-4221-9100-001","price":429.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KFTF-ECATP__tyr2-PA6-K_maxi-mL_4c.png?v=1769679126"},{"product_id":"kanal-feuchte-und-temperaturfuehler-2-0-hygrasgard-kftf-ecatp-lcd-ethercat-p-display-ip54-2003-4222-9100-001","title":"HYGRASGARD® KFTF-ECATP LCD","description":"Networkable duct humidity and temperature sensor HYGRASGARD® KFTF - EtherCAT P with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-release screws, optionally with\/without display and bar graph, with plastic sintered filter (replaceable), incl. mounting flange. \u003cbr\u003e\u003cbr\u003eThe sensor is used to determine various humidity measurement parameters. The relative humidity (0...100 % RH) and the temperature (- 35...+80 °C) of the ambient air are measured. Further output variables are calculated internally from these measured variables: absolute humidity (0...80 g\/m³), mixing ratio (0...80 g\/kg), dew point temperature (- 20...+80 °C) and enthalpy (0...85 kJ\/kg), disregarding the atmospheric air pressure. A long-term stable, digital sensor guarantees exact measurement results. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable measuring transducer for industrial requirements with maximum reliability: with simple integration into the PLC level via the ESI configuration file of the device, with diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255235608907,"sku":"2003-4222-9100-001","price":480.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KFTF-ECATP-LCD__tyr2-PA6-K_maxi-mL_4c.png?v=1769679173"},{"product_id":"druckmessumformer-fuer-differenzdruck-und-volumenstrom-premasgard-6127-ecatp-7000pa-2004-6271-9100-001","title":"PREMASGARD 6127-ECATP","description":"Networkable pressure transmitter PREMASGARD® 612x - EtherCAT P (series) PREMASGARD® 612x - ECATP with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, connection piece for pressure hose (Ø 6 mm), incl. connection set ASD-06 (2 m connection hose, two pressure connection nipples, screws).\u003cbr\u003e\u003cbr\u003e The surface-mounted sensor is used to measure positive, negative or differential pressures in clean air and gaseous media as well as for volume flow calculation via K-factor with function selection. The piezoresistive measuring element is temperature-compensated and guarantees high reliability and accuracy. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eIt is used in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spray booths and commercial kitchens, for filter monitoring and level measurement or for controlling frequency converters. The WS 03 weather and sun protection (accessory) must be used in direct sunlight. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable pressure transmitter for industrial requirements with maximum reliability: simple integration into the PLC level via the ESI configuration file of the device, diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, freely configurable LEDs) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255291904331,"sku":"2004-6271-9100-001","price":400.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/PREM-622x-ECATP__tyr2_maxi-mL_4c.png?v=1769663075"},{"product_id":"druckmessumformer-fuer-differenzdruck-und-volumenstrom-premasgard-6128-ecatp-500pa-2004-6271-9100-011","title":"PREMASGARD 6128-ECATP","description":"Networkable pressure transmitter PREMASGARD® 612x - EtherCAT P (series) PREMASGARD® 612x - ECATP with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, connection piece for pressure hose (Ø 6 mm), incl. connection set ASD-06 (2 m connection hose, two pressure connection nipples, screws).\u003cbr\u003e\u003cbr\u003e The surface-mounted sensor is used to measure positive, negative or differential pressures in clean air and gaseous media as well as for volume flow calculation via K-factor with function selection. The piezoresistive measuring element is temperature-compensated and guarantees high reliability and accuracy. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eIt is used in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spray booths and commercial kitchens, for filter monitoring and level measurement or for controlling frequency converters. The WS 03 weather and sun protection (accessory) must be used in direct sunlight. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable pressure transmitter for industrial requirements with maximum reliability: simple integration into the PLC level via the ESI configuration file of the device, diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255291969867,"sku":"2004-6271-9100-011","price":400.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/PREM-622x-ECATP__tyr2_maxi-mL_4c_28b25ccd-1918-48ad-afa1-91231b464163.png?v=1769663179"},{"product_id":"druckmessumformer-fuer-differenzdruck-und-volumenstrom-premasgard-6127-ecatp-lcd-7000pa-display-2004-6272-9100-001","title":"PREMASGARD 6127-ECATP LCD","description":"Networkable pressure transmitter PREMASGARD® 612x - EtherCAT P (series) PREMASGARD® 612x - ECATP with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, connection piece for pressure hose (Ø 6 mm), incl. connection set ASD-06 (2 m connection hose, two pressure connection nipples, screws).\u003cbr\u003e\u003cbr\u003e The surface-mounted sensor is used to measure positive, negative or differential pressures in clean air and gaseous media as well as for volume flow calculation via K-factor with function selection. The piezoresistive measuring element is temperature-compensated and guarantees high reliability and accuracy. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eIt is used in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spray booths and commercial kitchens, for filter monitoring and level measurement or for controlling frequency converters. The WS 03 weather and sun protection (accessory) must be used in direct sunlight. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable pressure transmitter for industrial requirements with maximum reliability: simple integration into the PLC level via the ESI configuration file of the device, diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255292297547,"sku":"2004-6272-9100-001","price":451.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/PREM-622x-ECATP-LCD-3174m3h__tyr2_maxi-mL_4c.png?v=1769663142"},{"product_id":"druckmessumformer-fuer-differenzdruck-und-volumenstrom-premasgard-6128-ecatp-lcd-500pa-display-2004-6272-9100-011","title":"PREMASGARD 6128-ECATP LCD","description":"Networkable pressure transmitter PREMASGARD® 612x - EtherCAT P (series) PREMASGARD® 612x - ECATP with M8 plug connector (EtherCATP-coded), Bluetooth-capable, in impact-resistant plastic housing with quick-locking screws, optionally with\/without display and bar graph, connection piece for pressure hose (Ø 6 mm), incl. connection set ASD-06 (2 m connection hose, two pressure connection nipples, screws).\u003cbr\u003e\u003cbr\u003e The surface-mounted sensor is used to measure positive, negative or differential pressures in clean air and gaseous media as well as for volume flow calculation via K-factor with function selection. The piezoresistive measuring element is temperature-compensated and guarantees high reliability and accuracy. The sensor is calibrated at the factory. \u003cbr\u003e\u003cbr\u003eIt is used in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spray booths and commercial kitchens, for filter monitoring and level measurement or for controlling frequency converters. The WS 03 weather and sun protection (accessory) must be used in direct sunlight. \u003cbr\u003e\u003cbr\u003eEtherCAT P-capable pressure transmitter for industrial requirements with maximum reliability: simple integration into the PLC level via the ESI configuration file of the device, diagnostic options (such as communication error counter), extended setting options, retrievable historical data (min\/max) and maintenance interval determination of the sensor. Optionally with large illuminated display (three lines, individually programmable in the 7-segment and dot-matrix area) and bargraph (seven digits, LEDs freely configurable) for graphical representation, e.g. as a traffic light display.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255292428619,"sku":"2004-6272-9100-011","price":451.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/PREM-622x-ECATP-LCD-3174m3h__tyr2_maxi-mL_4c_5c596d39-d11d-48ee-bb27-9293f2eaf408.png?v=1769663245"}],"url":"https:\/\/www.spluss.it\/en\/collections\/ethercat-p.oembed","provider":"S+S Regeltechnik","version":"1.0","type":"link"}